Treatment no.: |
4.4.4.7 |
ID no.: |
4.4.4.7 |
Position: |
Window frame |
Size: |
W510mm x L520mm x H280mm |
Damage Condition: |
crack, splitting |
Repair case: |
5a+5b |
Treatment | |
Specification: |
Connected by: Stainless screw bolt, Ø8mm x L150mm x 4ps |
|
Epoxy adhesive (B7 = 15ml) + (Sandstone Powder = 30g) |
|
Injection: Polymer( P-2e = 78g) + Cement (C-2 = 170g) |
|
Gap filling by: Polymer P-1c + Water + Cement + Sand + Metyl Cellulose |
Date of start: |
16 Jul 2007 |
Date of finish: |
23 Jul 2007 |
Person in charge: | Khieu Mony & Cheam Pross |