| Treatment no.: |
4.4.4.7 |
| ID no.: |
4.4.4.7 |
| Position: |
Window frame |
| Size: |
W510mm x L520mm x H280mm |
| Damage Condition: |
crack, splitting |
| Repair case: |
5a+5b |
| Treatment | |
| Specification: |
Connected by: Stainless screw bolt, Ø8mm x L150mm x 4ps |
| |
Epoxy adhesive (B7 = 15ml) + (Sandstone Powder = 30g) |
| |
Injection: Polymer( P-2e = 78g) + Cement (C-2 = 170g) |
| |
Gap filling by: Polymer P-1c + Water + Cement + Sand + Metyl Cellulose |
| Date of start: |
16 Jul 2007 |
| Date of finish: |
23 Jul 2007 |
| Person in charge: | Khieu Mony & Cheam Pross |