Treatment no.: |
4.4.14.12 |
ID no.: |
4.4.14.12 |
Position: |
Roof |
Size: | W500mm x L910mm x H300mm |
Weight: | 272kg |
Damage Condition: |
breakage, scale, |
Repair case: |
3+5a |
Treatment | |
Specification: |
Connected by: Stainless screw bolt, Ø6mm x L100mm x 6ps (50/50) |
|
Epoxy adhesive (B7 = 60ml) + (Sandstone Powder = 120g) |
|
Injection: Polymer( P-2e = 298g) + Cement (C-2 = 460g) |
|
Gap filling by: Polymer P-1c + Water + Cement + Sand + Metyl Cellulose |
Date of start: |
24 April 2007 |
Date of finish: |
22 May 2007 |
Person in charge: | Khieu Mony & Cheam Pross |