| Treatment no.: |
2.4.14.12 |
| ID no.: |
2.4.14.12 |
| Position: |
Roof |
| Size: |
L1007mm x W460mm x H240mm |
| Damage Condition: |
Fragment, Scaling |
| Repair case: |
1+5a |
| Treatment | |
| Specification: |
Epoxy adhesive (B7 = 7.5ml) + (Sandstone Powder = 15g) |
| |
Injection: Polymer( P-2e =46g) + Cement (C-2 = 50g) |
| |
Gap filling by: Polymer P-1c + Water + Cement + Sand + Metyl Cellulose |
| Date of start: |
11 Jun 2007 |
| Date of finish: |
20 Jun 2007 |
| Person in charge: | Khieu Mony & Cheam Pross |
Copyright ©2011 JASA: JAPAN + APSARA Safeguarding Angkor. All Rights Reserved.