| Treatment no.: |
2.4.12.15 |
| ID no.: |
2.4.12.15 |
| Position: |
Roof |
| Size: |
L820mm x W440mm x H260mm |
| Damage Condition: |
Crack, Splitting |
| Repair case: |
5a+5b |
| Treatment | |
| Specification: |
Connected by: Stainless screw bolt, Ø6 mm x L 120mm x 4ps |
| |
Epoxy adhesive (B7 = 15ml) + (Sandstone Powder = 30g) |
| |
Injection: Polymer( P-2e =56g) + Cement (C-2 = 60g) |
| |
Gap filling by: Polymer P-1c + Water + Cement + Sand + Metyl Cellulose |
| Date of start: |
27 Jun 2007 |
| Date of finish: |
03 Jul 2007 |
| Person in charge: | Khieu Mony & Cheam Pross |
Copyright ©2011 JASA: JAPAN + APSARA Safeguarding Angkor. All Rights Reserved.